Evaluation Method for Ion Migration Using Dew Cycle Test (Part 3)

For our report this time, we have designed prototype experimenting equipment enabling us to directly observe dew condensation conditions, thus allowing us to investigate the causes of Dendrites growing in the Dew Condensation Cycle Test. We have performed experiments to confirm changes in dew condensation conditions and also to confirm the relationship between dew condensation and the growth of Dendrites. At this time, we would like to report on the results of repeated test cycles confirming that water from dew condensation covering the gap between electrodes causes the substrate surface to become subject to wetting and causes Dendrites to grow.